LabSat3W - Technical Specificiation
LabSat 3 Wideband Technical Specificiation
Constellation |
GPS: L1, L2, L5; Galileo: E1, E5a/b, E6; GLONASS: L1, L2, L3; BeiDou: B1, B2, B3; QZSS: L1, L2, L5; NavIC L5 & S-Band; In Band SBAS, user defined frequency bands like Iridium & SiriusXM radio |
||
Nominal Output Signal Level |
-73 dBm/MHz @ 0 dB Variable attenuator provides between +20 dB and –69 dB of adjustment during replay |
||
RF Channels | 3 | ||
RF Channel 1 Centre Frequency | Selectable | ||
RF Channel 2 Centre Frequency | Selectable | ||
RF Channel 3 Centre Frequency | Selectable | ||
Number of Satellites Observed | All in view | ||
Sampling frequency | 10.23 MHz, 30.69 MHz, 58 MHz | ||
Bandwidth | 10 MHz, 30 MHz, 56 MHz | ||
Quantisation | 1, 2 or 3 bit (I & Q) | ||
Data Format | I & Q | ||
User Control | 6 Button Membrane Keypad | ||
Display | Backlit LCD Dotmatrix | ||
Additional Logging | 2 x CAN channels, 2 x Digital channels, 1 x RS232 channel | ||
Removable Battery Pack | Yes | ||
Media Storage Included | 1 TB SDD and 8 GB SD Card (SD card for firmware upgrade only) | ||
Active Antenna Voltage Supply | 2.8 - 4.6 V DC | ||
Reference Oscillator |
|
||
Operating Voltage | 8 - 30 V DC | ||
Size | 167 mm x 128 mm x 46 mm | ||
Weight | 1.2 kg | ||
Operating Temperature | 0°C to +60°C Note: Battery will not charge below 0°C or above +45°C (charger shuts down outside this range). Unit will shut down outside operating temperature range. | ||
Storage Temperature | -20°C to +60°C Note: Battery will discharge whilst in storage and discharge rate will increase at higher storage temperatures. |
LabSat 3 Wideband Dimensions
The LabSat 3 Wideband dimensions (mm):