The VBOX Micro can connect to any one of the following Racelogic input modules and then include the data from each channel in the logged VBO file. The VBOX Micro will automatically log all channels from a connected Input Module providing that the module is connected before the power is switched on.
Description | Part Numbers | Connection Cable |
---|---|---|
8 Channel Thermocouple Interface | RLVBTC8 | RLCAB063 |
8 Channel (10 bit) Analogue Interface | RLVBADC02 | RLCAB063 |
8 Channel (16 bit) Analogue Interface | RLVBADC03 | RLCAB063 |
4 Channel Frequency and Pulse Counter Input Module | RLVBFIM03 | RLCAB063 |
Mini Input Module | RLVBMIM01 | RLCAB063 |
Yaw Rate Sensor + 2-Axis G Sensor | RLVBYAW03 | RLCAB065 |
Inertial Measurement Unit | RLVBIMU04 | RLCAB065 |
Configuring the Input Modules
To configure an input module you must connect the module directly to the computer via a serial cable, the channels cannot be setup via the USB port on the VBOX Micro. The software required will be VBOX Setup - click here to check which modules support VBOX Setup.
The module can take power from the VBOX Micro both during operation and during configuration.